PVC Line Fire Hose
k3-0-brass-pendent-foam-water-sprinkler

  • Foam Nozzle Fire
    DN15 Foam Nozzle Fire
    DN15 Foam Nozzle Fire: Foam/water sprinkler systems are more economical than a water-only system, when evaluated for the same risk. They provide for actual extinguishment of the fire and a lower water demand. The conversion assists in the reductionof property loss, loss of life and in many cases the reduction of insurance rates. In most instances, fires cause more than structural and inventory damages. Many manufacturing and storage facilities have various flammable products that are protected by water sprinkler systems alone. The water sprinkler system may extinguish the fire; however, this type system has the two potential problems. If the water only system is not capable of quick extinguishment, the product containers can erupt and spill. Also it typically requires a great deal of water to extinguish a flammable liquid that is miscible in water or in many cases, the flammable liquid floats on the water and then the water becomes the vehicle that spreads the fire. Both the large amounts of water and the flammable liquids are normally washed into the local drain systems which can contaminate the water supplies and aquifers. Along with the financial loss of the manufacturing/storage facilities and products, there is the expense of contamination cleanup. Foam systems can facilitate in quick extinguishment and water reduction. In a single year, the National Fire Protection Association documented fires that involved flammable liquids with direct losses of over $1 billion. The extended losses includingthe close of businesses, cost of environmental cleanup and increased insurance costs are inconceivable.   Techincal Data: Sprinkler Body Material Brass Net Material SS304 Deflector Material Brass Installation Pendent Thread Connection 1/2" BSP Surface Finishing Brass Chromed Application Fire Protection Media Water ,Foam K Factor 3.0 Max Working Pressure 175 psi (12,1 bar) Size(mm) 15(1/2) 20(3/4) 25(1") Working Pressure(Mpa) 0.4 0.4 0.4 Flow Rate(L/S) 50 70 90 Foaming Level ≥5 ≥5 ≥5 25% dessection 120s 120s 120s K 25 35 45 Material Brass Brass Brass
    read more
  • Fire Water Nozzle
    400 - 2000LPM Fireman Holds and Adjust Fire Water Nozzle
    400 - 2000LPM Fireman Holds and Adjust Fire Water Nozzle Winner WFSN-2000 pistol grip fire nozzle is a constant gallonage nozzle(flow remains the same in all patterns), with multiple flow settings for operator flow control.The WFSN-950 has four flow classes,400-2000 LPS, and it is available both for straight stream,fog spray and flush without shutting down. Main Features 1) Pattern Identification. 2) Hard Anodized Aluminum labels,Laser Engraved. 3) Simple to operate (1/4 turn from straight stream to fog) 4) Raised lug marks straight stream for limited visibility operations  5) Easy to service and repair. 6) CCC certificate. 7) Compatible with Quick Attach Foam Tube   Product Parameter    Swivel Inlet 1.5" ( 40mm ) recommended Operation Type Pistol Grip Type Nozzle Type Automatic Nozzle,constant pressure, variable flow, constant gallonage, flow does not change with pattern Inlet Size 1.5 inch ,2 inch ,2.5 inch Coupling Storz/NH/BSP/Russian type, etc. Flow Rate 400-2000 L/min automatic Spray Pattern Jet and fog spray Media Water Application Fire fighting,fire hose,firefighter,fire hydrant Working Pressure 7 Bar Max Reach@Max Flow 60 Meters Max Fog Angle 120 degree
    read more
  • Fire Pump Connector
    Vietnam Throat to Receive Water Fire Pump Connector
    Vietnam Throat to Receive Water Fire Pump Connector It is used to supply water to the fire fighting system by pumping water directly into the throat. The equipment is attached to the fire-fighting water pipe.   Water-receiving plants or fire-fighting pillars are often installed in conjunction with a fire-fighting system. Used to pump water from fire engines for the system.   Specification Body material: Cast Iron  Outlet: DN65 Inlet: DN100 Working pressure: 10bar (KG/CM2) Finishing: Red Epoxy coated   2.Parameters Body       Ductile iron O-ring NBR Hose Outlet 2.5" Mounted Tooth and Lid  Aluminum Features: 1. Connect fire hose  with  water pipes quickly and conveniently. 2. Cast iron with high strength and durability. 3. An important equipment for urban roads, residential areas, industrial parks and some establishments where to guard public safety Just feel free to contact us or leave message for sample, price or details specifications, catalog or test report.
    read more
  • Fire sprinkler type,ZST fire sprinkler,CCC fire sprinkler,CE Fire sprinkler
  • Fire sprinkler with UL
  • 3mm Glass Bulb Fire Sprinkler
  • Fire sprinkler type,ZST fire sprinkler,CCC fire sprinkler,CE Fire sprinkler
  • Fire Valve Storz
    2 Inch Brass Oblique Fire Valve Storz
    2 Inch Brass Oblique Fire Valve Storz Fire Valve is a connector to fire water supply with the valve interface, used for factory, warehouse, high-rise buildings, public buildings and ship, normally installed in fire hydrant box, with fire hoses and water gun or wait for equipment supporting the fire equipment .   Type: Fire Valve Storz Model: WFHV - B50 Material: Brass Inlet interface: 50 mm / 2 inch Rated working pressure: 1.6 Mpa For water and foam mixed liquid only Standard: Manufacture and certified to DIN 14461    Name Indoor fire hydrant Body Material Brass Valve Rod Material Brass Size 50mm Packing Carton with pallet Delivery time 15-20 days OEM Avaliable Original Made In China
    read more
  • Thread Gate Valve
    Ductile Iron Water Seal Thread Gate Valve PN16
    Ductile Iron Water Seal Thread Gate Valve PN16 A gate valve, also known as a sluice valve, is a valve that opens by lifting a barrier (gate) out of the path of the fluid. Gate valves require very little space along the pipe axis and hardly restrict the flow of fluid when the gate is fully opened. The gate faces can be parallel but are most commonly wedge-shaped (in order to be able to apply pressure on the sealing surface).   Gate valves are used to shut off the flow of liquids rather than for flow regulation. When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low flow resistance.   Gate Valve Applications Gate valves are used in almost all fluid services such as air, fuel gas, feedwater, steam, lube oil, hydrocarbon, and all most any services. Some special gate valve is used in slurry and powder product also such as knife gate valve Advantages of Gate Valve Gate valve provides good pressure drop during operation  Most of the gate valve can be used as bi-directional They are suitable for high pressure and temperature application and required less maintenance
    read more
  • Pressure Release Valve
    Water Pressure Release Valve for Fire Fighting
    Water Pressure Release Valve for Fire Fighting The valve consists of the main valve and outside installed control pilot valve, mainly installed in the bypass of the protected water supply system in the building, guarantee the pressure of the main valve upstream water supply zone, when the pressure in the water supply pipe exceeds the pressure set by the pressure releasing valve, the pressure releasing valve is switched on to prevent pipeline and equipment from damage by pressure exceeding. This valve is mainly used in pressure releasing of the fire test circulation system in high-rise buildings, is the upgrade replacement product of the spring safety valve.   Features: 1)Reasonable and novel structure, reasonable use of the hydraulic principle to control. 2)Long service life. 3)Valve clack quick opening and slow closure, no water hammer impacting. 4)High sensitivity, safe pressure discharge. 5)Stable operation, no noise.
    read more
  • Pressure Relief Valve
    Water Pressure Relief Valve for Fire Fighting
    Water Pressure Relief Valve for Fire Fighting This valve is used for the high building fore-fighting system,To prevent the pipeline and equipment damage due to overpressure. The body uses full passage streamline design, of a small fluid resistance and a heavy flow. This valve can be used as either a pressure releasing or holding valve.  when used as the former, it can release the pressure surpassing the safe value set with the pilot valve and keep the pressure inside of the pipeline below the safe value to prevent system against danger due to an excessively high water pressure;while used as the latter,it can keep the upstream water supply pressure of the main valve over some set value,this is because water supply to the downstream can not be done,unless the upstream is higher than the set value,in order to make sure of he upstream water supply pressure of the main valve.
    read more
  • Water Gate Valve
    Ductile Iron Groove Type Signal 6 Inch Water Gate Valve
    Ductile Iron Groove Type Signal 6 Inch Water Gate Valve The signal gate valve is mainly used in the pipeline of the fire water system as a function of opening and intercepting the fluid in the pipeline, and converting the opening and closing working state into an electric signal through the signal device. The elastic seat sealing gate valve signal gate valve encapsulating the whole valve disc to generate a deformation compensation effect to achieve a good sealing effect, overcome the general gate valve sealing failure, water leakage, and rust phenomenon, more effective saving installation space.   It's mainly composed by the signal device, valve body, valve cover, disc assembly, stem, stem nut, hand wheel and other components. The annunciator is mainly composed of a transmission gear, a transmission rod and a micro switch. Gate Valve Applications Gate valves are used in almost all fluid services such as air, fuel gas, feedwater, steam, lube oil, hydrocarbon, and all most any services. Some special gate valve is used in slurry and powder product also such as knife gate valve Advantages of Gate Valve Gate valve provides good pressure drop during operation  Most of the gate valve can be used as bi-directional They are suitable for high pressure and temperature application and required less maintenance
    read more
  • High Velocity Water Spray Nozzle
  • Medium Velocity Spray Nozzles
  • Fire sprinkler type,ZST fire sprinkler,CCC fire sprinkler,CE Fire sprinkler
  • Fire Monitor
    Ductile Iron Fixed Manual Fire Water Monitor
    Ductile Iron Fixed Manual Fire Water Monitor PS series fire water cannon is a new type of multi-functional fire extinguishing equipment with high pressure and high strength material combination. It can be equipped on various fire trucks, fire boats, fixed fire turrets and fire pipes. The gun nozzle adopts the principle of diversion flow, namely large flow, concentrated water flow and long range flow. With many functions, it can be used for straight stream and spray. The flow rate can be adjusted within the range of 20-60L/S according to requirements. The operation is flexible and convenient, the gun body can be horizontally rotated, and the pitch can be turned upside down. The function of positioning and locking can be realized, which is convenient for the operator to evacuate the site and implement unmanned operation. Products Features 1, simple operation, flexible, long range 2, with flow adjustment function 3, horizontal rotation, pitch rotation 4, with straight stream and spary function Product Parameter Specification Rate Working Pressure(MPa) Max Working Pressure(MPa) Range(m) Flow Rate(L/S) Horizontal Rotation Ange(°) Max Elevation Angle(°) Max Depression Angel(°) Dimension PS20 0.8 1.0 ≥48 20 0~360 ≤+70 ≤-70 338*220*680 PS30 ≥55 30 ≤+70 ≤-70 338*220*680 PS40 ≥60 40 ≤+70 ≤-70 338*220*680 PS50 ≥65 50 ≤+70 ≤-70 338*220*680 PS60 ≥70 60 ≤+70 ≤-70 338*220*680
    read more

top

Online Now